8KW Hybrid Inverter (Single or Split Phase) (HB8KM100US)
Battery Input Details
Battery Type: Lead-acid or Lithium-ion
Battery Voltage Range: 40 - 60V
Maximum Charging Current: 190A
Maximum Discharging Current 190A
Charging Curve: 3 Stages / Equalization
External Temperature Sensor: Optional
Charging Li-Ion Battery: Self-adaption to BMS

PV Input
Max. DC Input Power: 10,400W
PV Input Voltage: Optimal 370V (100V-500V)
MPPT Range: 125V-425V
Start-up Voltage: 150V
No of MPPT Trackers: 2
No of Strings Per MPPT Tracker 2+2
PV Input Current: 22A+22A

AC Output
Rated AC Output and UPS Power: 8000W
Max. AC Output Power: 8800W
Surge Power (off  grid): 2 times of rated power, 10 S
AC Output Rated Current: 35A
Max. AC Current: 38.5A
Max. Continuous AC Passthrough: 50A
Grid Type: Single Phase or Split Phase
Output Voltage: 120/220Vac (Single phase), 120/240Vac (Split phase)
Output Frequency: 50 / 60Hz
Current Harmonic Distortion: THD<3% (Linear load<1.5%)

Efficiency
Max. Efficiency: 97.60%
Euro Efficiency: 97.00%
MPPT Efficiency: 99.90%
Protection: PV Input Lightning Protection Integrated
Anti-islanding Protection: Integrated
PV String Input Reverse Polarity Protection: Integrated
Insulation Resistor Detection: Integrated
Residual Current Monitoring Unit: Integrated
Output Over Current Protection: Integrated
Output Shorted Protection: Integrated
Output Over Voltage Protection: Integrated
Surge protection: DC Type II / AC Type II

Certifications and Standards
Grid Regulation: UL1741, IEEE1547, RULE21, VDE 0126, AS4777, NRS2017, G98, G99, IEC61683, IEC62116, IEC61727
Safety Regulation: IEC62109-1, IEC62109-2
EMC: EN61000-6-1, EN61000-6-3, FCC 15 class B

General Data
Operating Temperature Range: -25~60℃, >45℃ Derating
Cooling: Smart cooling
Noise: <30 dB
Communication with BMS: RS485; CAN
Weight: 32kg
Dimensions: (mm) 420W×670H×233D
Protection Degree: IP65
Installation Style: Wall-mounted
Warranty: 2 years
5.5 KW Hybrid Inverter (220V) (Can work without battery) (HB5KM100EU)
Nominal Input Voltage: 230Vac
Low Loss Voltage: 170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage: 180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage: 280Vac±7V
High Loss Return Voltage: 270Vac±7V
Max AC Input Voltage: 300Vac
Nominal Input Frequency: 50Hz/ 60Hz (Auto detection)
Low Loss Frequency: 40±1Hz
Low Loss Return Frequency: 42±1Hz
High Loss Frequency: 65±1Hz
High Loss Return Frequency: 63±1Hz
Output Short Circuit Protection: Circuit Breaker
Efficiency (Line Mode): >95% (Rated R load, battery full charged )
Transfer Time: 10ms typical (UPS); 20ms typical (Appliances)

Rated Output Power: 5.5KW
Output Waveform: Pure Sine Wave
Output Voltage Regulation: 230Vac±5%
Output Frequency: 50Hz
Peak Efficiency: 93%
Overload Protection: 5s@>150% load; 10s@110%-150% load
Surge Capacity: 2* rated power for 5 seconds
Nominal DC Input Voltage: 48Vdc
Cold Start Voltage: 46.0Vdc

Low DC Warning Voltage
@ load < 50%: 46.0Vdc
@ load > 50%: 44.0Vdc

Low DC Warning Return Voltage
@ load < 50%: 47.0Vdc
@ load > 50%: 46.0Vdc

Low DC Cut-off Voltage
@ load < 50%: 43.0Vdc
@ load > 50%: 42.0Vdc

High DC Recovery Voltage: 62Vdc
High DC Cut-off Voltage: 63Vdc
No Load Power Consumption: <35W

Utility Charging Mode
Charging Algorithm: 3-Step
AC Charging Current (Max): 80Amp (@Vi/p=230Vac)
Floating Charging Voltage: 54Vdc
MPPT Solar Charging Mode

Max. PV Array Power: 5500W
Nominal PV Voltage: 240Vdc
PV Array MPPT Voltage Range: 120-450Vdc
Max. PV Array Open Circuit Voltage: 500Vdc
Max Charging Current: 100Amp